Saving Results for an Aquifer

Aquifer pathways produce the following outputs:

   the total mass of each species in the pathway;

   the concentration of each species in the Reference Fluid exiting the pathway; and

   the mass flux of each species for any specified advective Outflows.

These outputs are all vectors by species.  Reference Fluid concentrations have dimensions of mass/volume.  Fluxes have dimensions of mass/time. 

You specify that you wish to save these results in two different places:

1.  Species masses in the pathway and concentrations in the Reference Fluid exiting the pathway are saved by clicking Final Values and/or Time History at the bottom of the Aquifer editing dialog:

A screenshot of a cell phone

Description automatically generated

2.  Fluxes are saved by selecting a mass flux link in the Inflows or Outflows tab for a linked pathway and clicking Save Final Values and/or Save Time History at the bottom of the dialog:

If you are running multiple realizations, the Time History box is ignored, and unless an output of the element is connected to a Time History Result element, no time history results will be saved at all for the element. In fact, in such a case, the Save Results section would look like this:

In this particular case, because the simulation involves multiple realizations, the “Time History” checkbox is replaced by a “Monte Carlo Histories” checkbox.  This checkbox is grayed out, since it is only used for information purposes.  You cannot edit it directly, and its appearance is completely determined by whether or not the output is connected to a Time History Result element.  That is, in order to save time history results for an Aquifer output when running multiple realizations, you must connect it to a Time History Result element.

The display units for masses, concentrations and fluxes for all pathways are specified in the Contaminant Transport tab of the Options dialog (accessed via Model | Options… from the main menu):

Related Topics…